pxi-8115 rt. 购买一个已带有双系统的. pxi-8115 rt

 
 购买一个已带有双系统的pxi-8115 rt If you don't see your specific PXI controller in the link, check for a PXIe driver of the same version

Title: NI-Obsolescence-for. With NI MAX open, start by refreshing the list of connected devices by clicking View»Refresh. 5 GHz Dual-Core Processor PXI Controller—The PXIe-8115 is a Intel Core i5 embedded controller for PXI systems. vi-> Get Portnames. Combining an PXI-8115 embedded controller with a PXI-compatible chassis,. This article explains how you canuse NI PXI controllers for chassis expansion via Thunderbolt™ in NI Linux Real-Time. ni pxie-8381 3. Manufacturer: National Instruments Model: PXI National Instruments PXI-8115 RT ControllerThe NI PXI-8115 RT (Part Numbers: 781862-33 and 781860-33) is an Embedded Controller manufactured by National Instruments, which performs around 48% higher than the PXI-. FM629-4. Best regards. Press <Delete> as the controller starts up to bring up the BIOS. Order by Part Number or Request a Quote. 有两种方法可以获得双系统控制器:. Benefits of PXI Express. the National Instruments PXIe-8115 embedded computer kit. 5. Real-Time PXI target: Ensure that LabVIEW Real-Time 8. Boot Setup Menu. Keysight Agilent HP M9036A. 4 buses. All Manuals. S. After that, you need to use VI server to make the deployed RT host VI run. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. Share this document with a friend. . The PXIe-8115 includes two 10/100/1000BASE-TX (Gigabit) Ethernet ports and six Hi-Speed USB ports, as well as an integrated hard. The formatter in. 2 & 3. 5 GHz Dual-Core Processor PXI Controller—The PXIe-8115 is a Intel Core i5 embedded controller for PXI systems. Click the " X " next to LabVIEW Real-Time. RT Series PXI controller, 2-1 to 2-3 procedure, 2-2 to 2-3 unsupported LabVIEW functions, 2-1 technical support resources, B-1 troubleshooting. 5 GHz Dual-Core Processor PXI Controller—The PXIe-8115 is a Intel Core i5 embedded controller for PXI systems. Boot Setup Menu. This chapter provides overview information for PXI Express and the . 重新启动控制器,然后按键盘上的 Delete 键进入BIOS。. 0. If you recently installed to a newer version of LabVIEW, try repairing the DAQmx driver. Manufacturer: National Instruments Model: PXI PXI-8119, 2. . 1. Fax: (240) 376-1381. RT Series PXI/CompactPCI Controller User Manual. used. I have a PXIe-1078 chassis with a PXIe-8115 controller running Pharlap. PXI Trigger Bus Input/Output. Check all that apply. PXIe, 2. used. Check part details, parametric & specs updated 29 OCT 2023 and download pdf datasheet from datasheets. Also, check Remote Port setting, as shown, check whether the port is already used by other applications or is blocked by Windows firewall. Configuring through NI MAX. . Manufacturer: National Instruments Model: PXIE PXIe-8115, 2. The PXIe-8115 includes two 10/100/1000BASE-TX (Gigabit) Ethernet ports and six Hi-Speed USB ports, as well as an. Here's a summary of my situation: An old system has PXI-8105 running WinXP; A new system has PXI -8115 running Win7; A hard drive (with Win7) from the PXI-8115 won't boot on the PXI-8105View online or download National instruments PXI-8115 User Manual. Added support for PXI controllers with NI Linux Real-Time—PXIe-8840 Quad-Core, PXIe-8861, and PXIe-8880. A. 5 GHz Intel. Find National Instruments and Agilent - Keysight for sale on Machinio. Added support for NI cRIO-9023, NI 9792, and EVS-146x Series. drag and drop the snippet onto a new vi, and then follow the selection. 6 GHz Dual Core Processor PXI Controller. 我有一个安装了 NI Linux RT 的 PXI 远程系统。. Find National Instruments and Hyster for sale on Machinio. National Instruments ran the benchmark utility on several RT targets within the CompactRIO and PXI product lines, including value, mainstream and high-performance targets. It is used for processor-intensive, modular instrumentation, and data acquisition applications. If the 8115 runs RT you would need a separate windows PC and target the 8115 from that. PXIe-8115 PXIe-8135 PXIe-8821 PXIe-8840 PXIe-8880 PXI-8102 PXI-8108. used. The power cord. Search for used rts. Am I missing some software package? Or do anyone have a suggestion? Best regards, Jørgen. Press <Delete> as the controller starts up to bring up the BIOS. In NI-XNET Bus Monitor, go to Settings» Interface and Database Settings and set Run. 29. Remember that nivs engine can run on windows or RT. 0. Find National Instruments, MSL, and ROC for sale on Machinio. With this change, support for many National Instruments software and drivers has changed. 05-04-2017 09:40 AM - edited ‎05-04-2017 09:47 AM. checking settings, 4-1. [Hardware] PXIe-1062Q - Quiet 8 slot PXI chassis, PXIe-8115 RT - Embedded Real-Time Controller (2. 1. How to Use the Documentation Set Begin by reading the NI PXIe-8115 Installation Guide, a brief quick-start guide that describes how to install and get started with your controller. NI PXI and PXI Express embedded controllers feature a variety of I/O conne ctivity to interface to stand-alone instruments or peripheral devices. 4. Find Aluma, National Instruments, BT, AMAT, Clausing, Kent, Norton, Schrader Bellows, Kramer, and Jeros for sale on Machinio. BIOS Diagnostic Utilities. This support no longer relies on VeriStand. I have tried this on two different PXI's and the same thing happens. Get a quote for a Used PXI 8115 Miscellaneous Controllers from Apex Waves, LLC at used-line. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. Return to Home Page. NI PXIe-8115. pxi rtコントローラのbios設定を変更して、ユーティリティusbドライブから起動する. Manufacturer: National Instruments Model: PXI PXI-8115, 2. View online (75 pages) or download PDF (750 KB) National Instruments PXI-8156, PXI-8150 Series, PXI-8155 User manual • PXI-8156, PXI-8150 Series, PXI-8155 PDF manual. Insert the IP Reset Disk into the controller, reboot it, and wait for the controller to finishing booting. Figure 3-10 shows the location and pinouts for the ExpressCard/34 slot on. 2. The PXIe‑8821 includes a 10/100/1000 BASE‑TX (Gigabit). In order to install LV RT, the HDDmustbeset toPrimary Master. To remove the unit from the PXI Express chassis: 1. 0 1. So if the 8115 runs windows you can run NIVS targeted at yourself. This section contains general installation instructions for the NI PXIe-8135. basic PXI system configuration, 2-23. PXIe-8115 PXI Express Embedded Controller PXIe-8840 PXIe-8133 PXI Express Embedded Controller PXIe-8840 PXIe-8135 PXI Express Embedded Controller PXIe-8840 National Instruments mature or obsolete products. ) Thanks for your replies. Combining an NI PXI-8115 embedded controller with a PXI-compatible chassis, such as the NI PXI-1042, results in a fully PC-compatible computer in a compact, rugged package. Turn off the PXI RT controller. Is PXI Platform Services 14. It worked on RTos very well with LabVIEW. The NI PXI-8115 RT (Part Numbers: 781862-33 and 781860-33) is an Embedded Controller manufactured by National Instruments, which performs around 48% higher than the PXI-8108. Web Server option dialog box, 2-3. Instead I tried to connect a USB-8473 CAN card to a USB socket on the front of the chassis on the assumption that I. Search for used rt. PXIe-8135 User Manual - NIThis document provides information about the PXIe-8135 , a high-performance embedded controller for PXI Express systems. NI PXI-8108 User Manual Index A. . 0 ni pxie-8364 ni pxie-8374 ni pxi-mxi-3 ni pxi-8364. This cable is recommended for various types of devices, such as the NI PXI-8115 RT, NI PXI-8135, and NI PXIe-8861. If you follow this step and you see a blank screen, press <F10> In the BIOS, navigate to the LabVIEW RT menu using the keyboard to navigate. For VeriStand, added support for PXI controllers with NI Linux Real-Time—PXIe-8840 Quad-Core and PXIe-8880. Manufacturer: National Instruments Model: PXI National Instruments PXI-8115 RT ControllerThe NI PXI-8115 RT (Part Numbers: 781862-33 and 781860-33) is an Embedded Controller manufactured by National Instruments, which performs around 48% higher than the PXI-. I'm using all LabVIEW 2011 versions of software with FPGA and RT modules. National Instruments PXI-8119 RT, 782555-33. NI PXI Express embedded controllers are compatible with a variety of PXI and PXI Express chassis and modules, and provide reliable and flexible solutions for. In this section you will configure the controller boot mode, verify or change IP settings, and install LabVIEW Real-Time software. PXI NI PXI-8115 User Manual NI PXI-8115 User Manual July 2012 373453C-01 Artisan Technology Group - Quality Instrumentation. com today. For example, PXIe-8115 peripheral drivers should work on the PXI-8115. Otherwise, just click OK without entering a password. 5. 01-07-2016 03:49 AM. I want to EtherCAT Master using Beckhoff C6015-0010 (C9900-C583) 05-02-2018 03:40 AM. Select the version of the Real-Time Operating system you want to install onto your PXI RT controller. 0. This article works as a standalone tutorial for installing software and is part of a series on migration to NI Linux RT: Determine compatibility Provision your PXI controller Install software Migrate Phar Lap application to NI Linux RT This. I need to reformat my PXI Real-Time (RT) controller which runs Phar Lap ETS. PXI Platform Services Hardware Support PXI Chassis 1. Manufacturer: National Instruments; Model: PXI; National Instruments PXI-8840 RT PXI Real-Time Controller The NI PXI-8840 RT is a PXI Real-Time Controller. 通过将控制器的硬盘分成两个分区,将现有的控制器更改为双系统. PXI-8115 Firmware and Additional Drivers provides support for the PXI-8115 PXI Controller. The exception is if you have purchased a PXI-8840, PXIe-8840, PXIe-8821 or PXIe-8880 controller with Windows 7 and would like to upgrade it to Windows 10. Order by Part Number or Request a Quote. 3 and PXIe-8115 controller running NI ETS 2009. NI PXIe-8115 embedded controller. Remember that nivs engine can run on windows or RT. In order to install LV RT, the HDDmustbeset toPrimary Master. 对于首次设置,建议使用以太网电缆直接连接上位机和远程系统,而不是通过路由器或其他媒介(例如 WiFi)。. In NI-XNET Bus Monitor, go to Settings»TCP/IP Settings: make sure that IP address of the real-time target is correct. 5 GHz Dual-Core Embedded Controller is an embedded computer and a high-performance PXI/CompactPCI system controller. LabVIEW is simple to utilize to obtain. ) Thanks for your answers. This cable is recommended for various types of devices, such as the NI PXI-8115 RT, NI PXI-8135, and NI PXIe-8861. Find Kawasaki, National Instruments, Grove, IMA, and Terex for sale on Machinio. On the. used. -A. You can indeed format many PXI RT controllers using a USB Utility Drive. We have New & Used PXI-8115 RT PXI Controllers by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. 9. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. the National Instruments PXIe-8115 embedded computer kit. Added support for new C Series modules. I am running FileZilla on a host PC connected to the target on a gigabit network, and I connected to the target via FTP using FileZilla and "pulled" the file from. This manual, the NI PXIe-8115 User Manual, contains more details about PXIe, 2. 1 or higher is installed on the development Windows PC. The PXI-8115 is run using the NI-DAQmx driver software which is compatible with software packages such as LabVIEW, Measurement Studio, LabWindows/CVI applications, or NI-VISA. No category . 2. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. Support Worldwide Technical Support and Product Information ni. See Determining and Upgrading PXI and VXI Embedded Controller BIOS Versions for information on determining and upgrading your controller's BIOS. The formatter in LabVIEW Real-Time (LV RT) 8. Systems Engineering Software. 0端口。Search for used process equipment and instrumentation. Or you could put hypervisor (if the 8115 supports it) to simultaneously run. Hard Drive. Power off the chassis. You can develop your LabVIEW application with the LabVIEW Real-Time Module onNational Instruments PXI-8115 RT, 781860-33, 781862-33. The benchmarking utility builds a performance profile which relates CPU Load to the number of shared variable updates per second. Change BIOS settings on the PXI RT controller to boot from the Utility USB Drive. Phar Lap notation is different than NI Linux RT notation. Find New Holland and National Instruments for sale on Machinio. Hard Drive. Approval certificaiton information for PXI controllers: NI PXIe-8135, NI PXIe-8135RT, NI PXI-8119 RT, NI PXIe-8115 RT, NI PXI-8115 RT, PXIe-8115 and NI PXI-8115 as listed by the Eurasian Economic Commision database of crpytographic related devices and tools. Engineers choose NI PXI because of its high measurement performance and proven. This document contains information about installing the NI PXI-8115 controller in a PXI chassis. See Determining and Upgrading PXI and VXI Embedded Controller BIOS Versions for information on determining and upgrading your controller's BIOS. 2. 1 or higher is installed on the development Windows PC. Note: For newer PXIe controllers like PXIe-8861 and PXIe-8881, skip steps 3 and 4. 5ghz controller, windows xp volatile memoryNational Instruments PXIe-8106. The NI PXI-8115 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, a s evidenced by receipts or other documentation. If your chassis is not listed above, you can check the user manual for your chassis and see if it has replacement procedures. Figure 2 shows a NI PXIe-8115 controller installed in the system controller slot of a NI PXIe-1082 chassis. 2 ni pxie-8820 3. NI PXIe-8115. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. LabVIEW RT Software Installation The following section describes the necessary steps to get your PXI embedded controller set up to run LabVIEW Real-Time. 5. How to Use the Documentation Set Begin by reading the NI PXIe-8115 Installation Guide, a brief quick-start guide that describes how to install and get started with your controller. Added support. NI PXIe-8115. PXIe-8108 (EOL 12-2014) replaced by PXIe-8115 PXI-7833R (EOL 12-2013) replaced by PXI-7842R Swapping 3. italic. Find National Instruments, Hyster, and Taylor for sale on Machinio. 3. 3. This article explains which versions of LabVIEW Real-Time and LabWindows/CVI Real-Time Module are supported by various PXI controllers. In an effort to take the PXI-8105 off-line to troubleshoot, I replaced it with one of the PXI-8115 and the old (WinXP) drive. 0 R 3. Find Genie, National Instruments, Halston, and Shindaiwa for sale on Machinio. 解决方案. A prompt to login as the admin user will appear. used. 2 2. 2. Manufacturer: Estone Technology Intel Core i3/i5 High Performance Fanless Computer with two HDMI and Dual Gigabit Ethernet The BIS-6861 is a small form factor fanless embedded PC based on Intel 5th Generation Core i3 or i5 Processor. new. Backplane bare-board material UL 94 V-0 Recognized Backplane connectors Conforms to IEC 917 and IEC 1076-4-101, UL 94 V-0 rated System Synchronization Clocks 10 MHz System Reference Clock: PXI_CLK10. Insert the IP Reset Disk into the controller, reboot it, and wait for the controller to finishing booting. bios를 켜려면 컨트롤러가 시작되면 <삭제(delete)> 를 누르십시오. PXI-8115 PXI-8119. Open MAX and expand Remote Systems. Drivers and Updates: NI PXI (e)-8135/8115/8119 Target CD 1. Search for used 33 in. Trusted Seller. Labview RT Configuration Overrides Submenu. Engineers use NI PXI to build high-performance, mixed-measurement systems for validation and production test. 1)I tried to deploy the example of sinewave delay to PXI 8115 RT system,but the deployment failed with this error message,What causes the error, andThe NI PXI-8145RT has a high MTBF (mean time between failures) of 281,262 h. National Instruments PXI-8115. NI PXIe-8115 Installed in a PXI Express Chassis How to Remove the Controller from the PXI Express Chassis The NI PXIe-8115 controller is designed for easy handling. Ensure PXI target is running the latest BIOS that support ETS with Reliance. PXIe, 2. com. The National Instruments PXIe-8115 (Part Numbers: 781729-04 and 781729-33) Controller can be used in conjunction with a PXI Express-compatible chassis, such as the PXIe-1082, with the result of a PC-compatible computer. Download the product flyer to learn more about the features and specifications of NI PXI Express embedded controllers, which offer high-performance computing and data streaming for PXI systems. The formatter in LabVIEW Real-Time (LV RT) 8. Navigate to the Power/Wake Configuration menu. Find Genie, Skyjack, National Instruments, Sorvall, and IKA for sale on Machinio. SPECIFICATIONS PXI-1031/PXI-1031DC This document includes specifications for the PXI-1031 and PXI-1031DC chassis. 5. This pc is ultra compact industrial PC with ethernet 2 ports. NI PXIe-8115 User Manual. . If you follow this step and you see a blank screen, press <F10> In the BIOS, navigate to the LabVIEW RT menu using the keyboard to navigate. 0 2. It is a test and measurement platform that combines a controller with measurement instruments in a multi-slot chassis. Turn off the PXI RT controller. RT Target: Miscellaneous, 2-6 to 2-7. · This manual, the NI PXIe-8115 User. 18. Search for used general process systems. Find Halston, CWP, Littell, National Instruments, Philips, Nissei, and Sciex for sale on Machinio. Remove the disk, insert the RT PXI Boot Disk if necessary, and reboot the controller. Consult the NI PXI-8115 User Manual for specific instructions and warnings. National Instruments PXI-8820 RT. Am I missing some software package? Or do anyone have a suggestion? Best regards, Jørgen. . used. I think you can use C: i-rt\startup folder to put your RT Host VI. 1. 3. I've just had the same kind of problem : trying to install Veristand on PXI (8115) from MAX but the paths are not entirely visible (see attached screenshot). 5. The power cord. 1 3. Search for used rt 7. 5 GHz Dual-Core Processor PXI Controller—The PXIe-8115 is a Intel Core i5 embedded controller for PXI systems. TBirkulosis. Its as if some device in the system is triggering hardware interupts thus forking execution time away from the POST, BIOS, boot menu and OS software. I/O offerings include up to two Thu nderbolt 3, two USB 3. Mi controlador PXI es capaz de arrancar desde el Sistema Operativo LabVIEW RT y Windows/Otro. Research Reveals How Test Can. I have a Beckhoff C6015-0010 (with C9900-C583). System CMOS. . Contact us with questions for pricing. Best Regards. Best Regards. In NI-XNET Bus Monitor, go to Settings»TCP/IP Settings: make sure that IP address of the real-time target is correct. PXI Real-Time controller, and using our extensive knowledge of NI VeriStand we were able to offer a real-time test (HiL) engine that gives the customer a very flexible solution. PXIe-8115: 7. Find National Instruments, Easy Kleen, John Deere, APC, and Wysong for sale on Machinio. 373721A-01. Systems Engineering Software. On the NI PXIe-1078 backplane is a. 31. National Instruments PXI-8115 RT, 781860-33, 781862-33. The formatter in. 5. com. They do not support Phar Lap OS and thus do not have a LabVIEW RT configuration option. Try searching for what you need. A dialog will appear that will allow you to install the appropriate software to your controller (see Figure 4). Trusted Seller. 2. Has anyone else had this problem with the PXIe-8115 on the PXIe-1082-BP backplane. 0 2. , and measures 1. -A. Controllers configured for LabVIEW RT provide a 80 GB (minimum) SATA hard drive. 16 GHz Dual-Core Processor, PXI Embedded Controller National Instruments PXIe-8106 PXI Controller The PXIe-8106 (Part Numbers: 779920-00, 779920-01, 779921-00, and 779921-01) is a Dual-Core Processor,. 5ghz controller, windows 7 153201a-922l or later ni pxi-8115,intel core i5 2. Using incompatible versions may result in errors, the inability for RTOS to recognize or detect and then. You have to build PXI-Real Time code. 07-01-2013 05:40 AM. Press <Delete> as the controller starts up to bring up the BIOS. Sign In Upload. National Instruments PXIe-2725. Or you. ), refer to the NI PXI-8115 User Manual. National Instruments PXI-8115 RT Controller. I installed NI Real-Time Desktop PC in this. The PXIe‑8821 includes a 10/100/1000 BASE‑TX (Gigabit) Ethernet. F or example right arrow key to move from Advanced to LabVIEW RT takes about 1 second before it completes followed by a. It is used for processor-intensive, modular instrumentation, and data acquisition applications. Manufacturer: National Instruments Model: PXI National Instruments PXI-8115 RT ControllerThe NI PXI-8115 RT (Part Numbers: 781862-33 and 781860-33) is an Embedded Controller manufactured by National Instruments, which performs around 48% higher than the PXI-. 5. Since these are sold in both OS variants, you can do this upgrade by either purchasing Windows 10 license from Microsoft and performing a clean install on your controller or by. NI PXIe-8115 User Manual and Specifications - National. Dual-Core Embedded Controller by National Instruments - PXI-8115 The Dual-Core Embedded Controller PXI-8115 (with part numbers including 781862-00, 781860-33, 781862-04, and 781860-01) is specifically engineered by National Instruments. LabVIEW RT and NI-DAQ to create embedded, real-time applications that run on an RT Series PXI controller. used. 53 GHz dual core), 6 MB shared L2 Cache,. io; Blog; Search;Search for used 33 rts. The exception is if you have purchased a PXI-8840, PXIe-8840, PXIe-8821 or PXIe-8880 controller with Windows 7 and would like to upgrade it to Windows 10. used. View online or download National instruments PXI Series User Manual, Installation Manual. Create the RT PXI IP Reset Disk in Measurement & Automation Explorer by selecting Tools»RT Disk Utilities»Create IP Reset Disk. The PXI (PCI eXtensions for Instrumentation) industry standard, an open specification governed by the PXI Systems Alliance (PXISA), has quickly gained adoption and grown in prevalence in test,. Is there any way to get the ACTUAL CPU frequency (mine should be up to 3. Thanks very much! Try going to MAX and installing some software in your PXI, there it will propt a windows giving you steps to install the base file. It has a recommended operating temperature range of 0 to 50 °C, and a storage temperature range of –20 to 70 °C. you have to use the system thingy and then with a property node "system resource" and only then will you find the "cpu speed". 34. PXIe-8115 Firmware and Additional Drivers includes a device driver as firmware for the PXIe-8115 PXI Controller. A visit to National Instruments products page showed that there is a version of 8115 shipped with Windows XP/7 operating system, but it looks like it doesn't support real-time applications, as there is a RT version as well, for. Item is sold as pictured. . 5. Below is a compatibility chart for your reference. 3. For Linux RT based systems, see here. National Instruments PXI-8119. 6 GHz 8-Core PXI Controller The PXIe‑8862 is an Intel Core i7 8‑Core embedded controller for PXI Express systems. Solved! Go to Solution. The module has a 2. Mi controlador PXI es capaz de arrancar desde el Sistema Operativo LabVIEW RT y Windows/Otro. Find National Instruments and Hyster for sale on Machinio. 5. It is used for processor-intensive, modular instrumentation, and data acquisition applications. LabVIEW RT Configuration Switches section or the LabVIEW RT Setup Menu section in this document to configure the controller for booting into LabVIEW RT. Select the NI PXI-6682 (H) or NI PXI-6683 (H) in your chassis and select the Test Panels button. Re: How to get CPU speed on RT devices (PXIE-8115) jwscs. Find New Holland and National Instruments for sale on Machinio. Boot Settings Configuration Submenu. Press <Delete> as the controller starts up to bring up the BIOS. National Instruments PXI-8840 RT PXI Real-Time Controller The NI PXI-8840 RT is a PXI Real-Time Controller. This manual, the NI PXIe-8115 User Manual, contains more details about 因此此模式无法兼容PharLap RT系统,因为后者需要传统引导和MBR分区硬盘驱动器。. 若使用此方式,NI对PXIe控制器的任何故障概不负责。. I have tried two different real-time setups. Manufacturer: National Instruments Model: PXIE PXIe-8106, 2. 2. 12-26-2007 01:41 PM. . We have New & Used PXI-8115 RT PXI Controllers by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. National Instruments PXI-8115 RT, 781860-33, 781862-33. 有两种方法可以获得双系统控制器:. 2.